Ex and Exi basic

Course on electrical installations and intrinsically safe systems in hazardous areas.
10-14. juni 2024
Zobacz godziny
10. juni 2024 - 09:00:16:00
11. juni 2024 - 08:30:16:00
12. juni 2024 - 08:30:16:00
13. juni 2024 - 08:30:16:00
14. juni 2024 - 08:30:16:00
Norwegian
09-13. sep. 2024
Zobacz godziny
09. sep. 2024 - 09:00:16:00
10. sep. 2024 - 08:30:16:00
11. sep. 2024 - 08:30:16:00
12. sep. 2024 - 08:30:16:00
13. sep. 2024 - 08:30:16:00
Norwegian
07-11. okt. 2024
Zobacz godziny
07. okt. 2024 - 09:00:16:00
08. okt. 2024 - 08:30:16:00
09. okt. 2024 - 08:30:16:00
10. okt. 2024 - 08:30:16:00
11. okt. 2024 - 08:30:16:00
Norwegian
28. okt.-01. nov. 2024
Zobacz godziny
28. okt. 2024 - 09:00:16:00
29. okt. 2024 - 08:30:16:00
30. okt. 2024 - 08:30:16:00
31. okt. 2024 - 08:30:16:00
01. nov. 2024 - 08:30:16:00
Norwegian
02-06. des. 2024
Zobacz godziny
02. des. 2024 - 09:00:16:00
03. des. 2024 - 08:30:16:00
04. des. 2024 - 08:30:16:00
05. des. 2024 - 08:30:16:00
06. des. 2024 - 08:30:16:00
Norwegian
Oferujemy także zorganizowanie kursu na miejscu - w Twojej firmie

Purchase this and other courses on trainor.no.

Rodzaj kursu
Stacjonarny
Wykłady na żywo z doświadczonym instruktorem.
Czas trwania
5 dni
Ile czasu zajmuje kurs. Szczegóły znajdziesz w tabeli kursów.
Język
NorwegianNorwegian
EnglishEnglish
Język, którym będzie posługiwał się instruktor podczas kursu.
Dostawca
Trainor
Kto wyprodukował i jest odpowiedzialny za treść kursu.

Cel

This course teaches participants to interpret zone maps and install electrical equipment in hazardous areas, and install and calculate the function and safety of intrinsically safe electrical circuits in hazardous areas.

Grupa docelowa

Electricians, technicians, engineers, automation technicians and others who work with measuring and control signals in Ex areas.

Kurs zawiera te przedmioty

  • Zone classification
  • Explosion theory
  • Equipment categories and gas grouping
  • Ex Installation Guide as related to EN/IEC 60079-14 Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines) and IEC 61892-7 Mobile and fixed offshore units - Electrical installations - Part 7: hazardous areas
  • Protection methods
  • Marking
  • Temperature classes
  • IP classification
  • Cables
  • Glands
  • Earthing
  • Intrinsic Safety - philosophy
  • IS marking
  • Extractions from EN 60079-11 Intrinsically safe apparatus (Exi)
  • Energy limitation
  • Zener barriers
  • Calculations
  • Connections
  • Galvanic isolators
  • IS applications
  • Installation
  • Practical exercises in selection and installation of zener barriers.

Przepisy

According to guidelines from Offshore Norway (059) and the NFEA Ex-KOMP:2021 guidelines for training, the competence should be updated at least every five years.

Informacje techniczne

Podręcznik do kursu

Tak, na początku kursu zostanie dostarczony podręcznik do kursu.

Powiązane kursy

Download Trainor app

You can complete eLearning courses from a mobile or tablet on the Trainor App. The free app can be used without an internet connection, offering flexibility in where and when learning takes place.

Trainor App